For complete information, refer to the appropriate installation and programming guides from DMP.com/global-dealer-products.
To add an access door to be managed in Virtual Keypad, complete the following steps:
Add the Device
-
Go to Customers.
-
Select the system name.
-
In the menu, go to Programming.
-
Expand Device Setup.
-
Select Add Device.
-
In Device Name, give the door a name according to its location or purpose.
-
In Device Type, select Door.
-
To make the door a private door that can only be accessed by the profiles it’s assigned to, turn on Private Door.
-
In Device Communication Type, select the appropriate connection for the door.
-
Configure other options as needed.
-
To add a card format, expand Card Formats, select Add Card Format, and configure the options as needed.
-
Select Send Device Setup.
Add the Door to Virtual Keypad
-
In the menu, go to System Information and select Edit.
-
Go to Virtual Keypad Access.
-
In Door Control, select Add.
-
Select the doors that you want to add, then select OK.
-
Select Save.
Configure Profile Options
-
In the menu, go to Profiles.
-
In the row of the profile that you want to edit, select the Settings icon. Otherwise, create a new profile.
-
In Access Areas, select the areas that you want profile users to have the ability to access.
-
If necessary, go to Private Doors and select the doors that you want profile users to access.
-
In Options, select the access control options that you want profile users to have. For more information, refer to Access Control Profile Options.
-
Select Send Changes to System.
Access Control Profile Options
These access control options allow profile members to perform the following actions:
-
Door Lock/Unlock—Lock and unlock doors.
-
Door Access—Temporarily unlock a door for access.
-
Lockdown—Initiate a lockdown.
-
Sensor Reset—Reset all system sensors. A sensor reset is required for system restoral after a lockdown is ended (Lockdown Override).
-
Lockdown Override—End a lockdown and restore the system. Sensor Reset is also required to override a lockdown.
-
Anti-Passback—Require anti-passback. Profile members are required to properly exit (egress) an area previously accessed. Users cannot re-access the area until they properly exit it. Egress Areas are configured in Device Setup.
-
Card Plus Pin—Require Card Plus Pin. Profile members are required to use two access methods to operate the system from a keypad. The first method must be a credential such as a proximity patch, card, or key fob. The second method must be a PIN number entered at the keypad.
-
Dual Authority—Require Dual Authority. Two user codes must be entered within 30 seconds of each other at a system keypad to arm or disarm a specific area. Dual Authority must be enabled in Area Information to use this feature.